The Citicorp Tower, also known as 601 Lexington Avenue, is a skyscraper located in New York City. It was completed in 1977 and was designed by Hugh Stubbins and Associates, with the structural engineering provided by Leslie E. Robertson Associates. At the time of its construction, the Citicorp Tower was the seventh tallest building in the world and the tallest in New York City, with a height of 915 feet (279 meters). It remained the tallest building in New York City until it was surpassed by the World Trade Center in 1970.

One of the most distinctive features of the Citicorp Tower is its 45-degree angled top, which was designed to provide additional space for mechanical equipment and to reduce the wind loads on the building. The building also has a unique structural system, which consists of a steel frame with diagonal braces that provide lateral stability. This system allows the building to have a more open and flexible floor plan, as the diagonal braces do not obstruct the interior space.

The Citicorp Tower was designed to be energy efficient and environmentally friendly, with features such as energy-efficient windows, low-flow plumbing fixtures, and a cooling system that uses rainwater to cool the building. It also has a green roof, which helps to reduce stormwater runoff and heat island effect, and a solar panel array, which generates electricity for the building.

The Citicorp Tower is home to a variety of businesses and organizations, including Citigroup, law firms, and media companies. It also has a shopping center and a public plaza, which are open to the public. The building has received numerous awards for its design and sustainability features, including the American Institute of Architects' National Honor Award for Architecture.

In conclusion, the Citicorp Tower is a notable example of modernist architecture and sustainable design. Its distinctive angled top and innovative structural system set it apart from other skyscrapers, and its energy-efficient and environmentally friendly features make it a model for future buildings.

The Citicorp Centre Tower: Almost a Tragedy

citicorp tower case

Retrieved April 5, 2021. To save money, Bethlehem Steel changed the plans in 1974 to use bolted joints, which was accepted by LeMessurier's office but not known to the engineer himself. Retrieved April 6, 2021. By that time, LeMessurier had died. The New York Times.

Next

How the Citicorp Center nearly toppled and other NYC building fiascos

citicorp tower case

He never warned the workers and the public living in that area as well as the people working in the Citicorp tower. Retrieved April 5, 2021. After the building's completion, it received mixed reception. Retrieved January 25, 2021. Retrieved April 5, 2021. Emergency consultations in Canada with the director and staff of the wind tunnel laboratory, where tests had been run on a model of the tower while it was still in design during 1973, led to appreciation that the problem was significantly more critical than he had realized. Peter's Lutheran Church, which had been founded in 1862 as a German-speaking congregation.

Next

Examining the Citicorp case: ethical paragon or chimera

citicorp tower case

It was the seventh tallest tower in the city. A permit was refused to be granted for residential use. If the issues were made known to the public, he risked ruining his professional reputation as well as causing panic in the immediate area surrounding the building, as well as to occupants. Citicorp Center was the subject of broad attention as well as great praise in the popular media. Privately Owned Public Space: The New York City Experience. Peters Lutheran under the condition that the church was conserved and didnt have to be demolished.


Next

Citigroup Center

citicorp tower case

Retrieved April 5, 2021. Retrieved August 11, 2020. Even after the solar-collector plans were scrapped, the design was kept; Stubbins wrote that the roof "relieves the uniformity of flat-topped towers proliferating in the center of the city". New York 2000: Architecture and Urbanism Between the Bicentennial and the Millennium. Working with other consultants, LeMessurier designed an innovative system to diminish the accelerations caused by the vibration. PDF from the original on August 3, 2021.

Next

Citicorp Center engineering crisis

citicorp tower case

This activity does not abide by an architects export duty. I was constantly calculating which joint to fix next, which level of the building was more critical, and I developed charts and graphs of all the consequences: if you fix this, then the rarity of the storm that will cause any trouble lengthens to that. Retrieved April 5, 2021. Financing American enterprise: the story of commercial banking. Others have made evident their desire to avoid comment.

Next

(Re)examining the Citicorp Case: ethical paragon or chimera?

citicorp tower case

All the work should be used in accordance with the appropriate policies and applicable laws. Retrieved April 5, 2021. She made her own calculations. At that point, the vertex was lifted up to the top of the Chrysler Building. The tower incorporated an array of notable technological features including doubledecker elevator cabs to reduce the number of elevator shafts and thereby increase the usable floor area, alternative energy source and reclamation systems, and low-brightness lighting that helped render the tower some 42% more energy efficient than comparable structures designed to conventional standards. The organization, before settling on the choice of changing the joints ought to have sat down with the partners, kindred specialists, and the expert before rolling out any improvement in the building plan.

Next

The Citicorp Tower blog.sigma-systems.com

citicorp tower case

He drew a plan for correcting his problem and immediately informed the owners of the tower of what he determined. At the point when a noteworthy take off from the development records are proposed for a basic framework influencing the wellbeing, security, and welfare of the general population, the choice should include the key people associated with the outline of the framework. The financial institution began planning to establish a new building on the churchs block. Retrieved April 3, 2021. For each year the Citicorp Center stood, LeMessurier figured, it stood about a one in 16 chance of collapsing. The New York Times.

Next

đź“š Citicorp Center Tower: How Failure Was Averted

citicorp tower case

This is a purely intellectual exercise, as it was generally believed that, if a building can withstand perpendicular wind, it should be able to withstand quarterly winds as well. He opted that the only way out is to blow the whistle on himself. The Citicorp Center engineering crisis was the discovery, in 1978, of a significant structural flaw in In the original design, potential wind loads for the building were calculated incorrectly. Retrieved April 6, 2021. Nonetheless, as a safeguard, Citicorp worked out crisis departure designs with nearby authorities for the quick neighborhood. Citicorp Building Engineering Ethics Topic.

Next

Citicorp case study

citicorp tower case

Retrieved April 17, 2014. Retrieved January 1, 2021. The organization ought to have instantly halted their development function when they realized their fault. Stamford, CT: Wadsworth: 2000 7. Some of these thoughts on Citicorp Center tower have been shared with design professionals and with academic colleagnes in the United States and Australia. New life for plazas. We are a very cautious organization—we wear both belts and suspenders here.